Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Cardiovasc Med ; 11: 1298466, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38450373

RESUMEN

Objectives: Minimally-invasive direct coronary artery bypass (MIDCAB) is a less-invasive alternative to full sternotomy off-pump coronary artery bypass (FS-OPCAB) revascularization of the left anterior descending artery (LAD). Some studies suggested that MIDCAB is associated with a greater risk of graft occlusion and repeat revascularization than FS-OPCAB LIMA-to-LAD grafting. Data comparing MIDCAB to FS-OPCAB with regard to long-term follow-up is scarce. We compared short- and long-term results of MIDCAB vs. FS-OPCAB revascularization over a maximum follow-up period of 10 years. Patients and methods: From December 2009 to June 2020, 388 elective patients were included in our retrospective study. 229 underwent MIDCAB, and 159 underwent FS-OPCAB LIMA-to-LAD grafting. Inverse probability of treatment weighting (IPTW) was used to adjust for selection bias and to estimate treatment effects on short- and long-term outcomes. IPTW-adjusted Kaplan-Meier estimates by study group were calculated for all-cause mortality, stroke, the risk of repeat revascularization and myocardial infarction up to a maximum follow-up of 10 years. Results: MIDCAB patients had less rethoracotomies (n = 13/3.6% vs. n = 30/8.0%, p = 0.012), fewer transfusions (0.93 units ± 1.83 vs. 1.61 units ± 2.52, p < 0.001), shorter mechanical ventilation time (7.6 ± 4.7 h vs. 12.1 ± 26.4 h, p = 0.005), and needed less hemofiltration (n = 0/0% vs. n = 8/2.4%, p = 0.004). Thirty-day mortality did not differ significantly between the two groups (n = 0/0% vs. n = 3/0.8%, p = 0.25). Long-term outcomes did not differ significantly between study groups. In the FS-OPCAB group, the probability of survival at 1, 5, and 10 years was 98.4%, 87.8%, and 71.7%, respectively. In the MIDCAB group, the corresponding values were 98.4%, 87.7%, and 68.7%, respectively (RR1.24, CI0.87-1.86, p = 0.7). In the FS group, the freedom from stroke at 1, 5, and 10 years was 97.0%, 93.0%, and 93.0%, respectively. In the MIDCAB group, the corresponding values were 98.5%, 96.9%, and 94.3%, respectively (RR0.52, CI0.25-1.09, p = 0.06). Freedom from repeat revascularization at 1, 5, and 10 years in the FS-OPCAB group was 92.2%, 84.7%, and 79.5%, respectively. In the MIDCAB group, the corresponding values were 94.8%, 90.2%, and 81.7%, respectively (RR0.73, CI0.47-1.16, p = 0.22). Conclusion: MIDCAB is a safe and efficacious technique and offers comparable long-term results regarding mortality, stroke, repeat revascularization, and freedom from myocardial infarction when compared to FS-OPCAB.

2.
Eur Heart J Case Rep ; 8(1): ytad640, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38213867

RESUMEN

Background: In more than 90%, transcatheter aortic valve implantation (TAVI) is performed via transfemoral access. Alternative access routes are necessary for patients with unfavourable femoral arteries. Case summary: We report of a 68-year-old female with symptomatic severe aortic stenosis in whom surgical aortic valve replacement was prohibited due to her severe co-morbidities. Both femoral arteries and both subclavian arteries were unsuitable for TAVI access. Surgical aortic valve replacement and transapical TAVI were deferred due to extremely high operative risk and very low originating left coronary artery of 7 mm from the annulus. Hence, we decided to implant a self-expanding TAVI device with a low risk of coronary obstruction (Acurate Neo 2 prosthesis) via transaortic approach, which to our knowledge is the first case worldwide. Conclusion: The present case demonstrates the feasibility of implanting the Acurate Neo 2 system via transaortic approach when certain key points are respected. Transaortic TAVI with the Acurate Neo 2 offers a minimally invasive treatment of high operative risk patients with low originating coronary arteries.

3.
J Clin Med ; 11(15)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35956185

RESUMEN

BACKGROUND: Treatment of severely calcified aortic valve stenosis is associated with a higher rate of paravalvular leakage (PVL) and permanent pacemaker implantation (PPI). We hypothesized that the self-expanding transcatheter heart valve (THV) prostheses Evolut Pro (EPro) is comparable to the balloon-expandable Sapien 3 (S3) regarding hemodynamics, PPI, and clinical outcome in these patients. METHODS: From 2014 to 2019, all patients with very severe calcification of the aortic valve who received an EPro or an S3 THV were included. Propensity score matching was utilized to create two groups of 170 patients. RESULTS: At discharge, there was significant difference in transvalvular gradients (EPro vs. S3) (dPmean 8.1 vs. 11.1 mmHg, p ≤ 0.001) and indexed effective orifice area (EOAi) (1.1 vs. 0.9, p ≤ 0.001), as well as predicted EOAi (1 vs. 0.9, p ≤ 0.001). Moderate patient prosthesis mismatch (PPM) was significantly lower in the EPro group (17.7% vs. 38%, p ≤ 0.001), as well as severe PPM (2.9% vs. 8.8%, p = 0.03). PPI and the PVL rate as well as stroke, bleeding, vascular complication, and 30-day mortality were comparable. CONCLUSIONS: In patients with severely calcified aortic valves, both THVs performed similarly in terms of 30-day mortality, PPI rate, and PVL occurrence. However, patient prothesis mismatch was observed more often in the S3 group, which might be due to the intra-annular design.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...